Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revisionBoth sides next revision | ||
livebox:hah_hahnode:airwick [2012/05/22 12:11] – [Assembly instructions for the Airwick] minerva9 | livebox:hah_hahnode:airwick [2012/05/28 15:02] – [Assembly instructions for the Airwick] minerva9 | ||
---|---|---|---|
Line 2: | Line 2: | ||
{{6929394483_150611e518_q.jpg }} | {{6929394483_150611e518_q.jpg }} | ||
- | The Airwick iMotion Freshmatic Compact makes an ideal housing for a [[/ | + | The Airwick iMotion Freshmatic Compact makes an ideal housing for a [[/ |
- | Each Airwick roomNode adds one temperature sensor (via a DS18B20), movement detection via the inbuilt Airwick PIR, light level detection via an LDR and a low battery warning (the batteries last for a very long time). Totally wireless in operation, so just place the roomNode where you need to take the readings. | + | Each Airwick roomNode adds one temperature sensor (via a DS18B20), movement detection via the inbuilt Airwick PIR, light level detection via an LDR and a low battery warning (the batteries last for a long time). Totally wireless in operation, so just place the roomNode where you need to take the readings. |
- | You can buy the roomNode Airwick kit from the Shop. This kit includes includes all connector cables and sensors. | + | You can buy the roomNode Airwick kit from the [[http:// |
An assembled roomNode control unit showing the location for each of the sensors used by the Airwick. | An assembled roomNode control unit showing the location for each of the sensors used by the Airwick. | ||
Line 22: | Line 22: | ||
[3] = RoomNode{base=" | [3] = RoomNode{base=" | ||
</ | </ | ||
- | |||
===== Assembly instructions for the Airwick ===== | ===== Assembly instructions for the Airwick ===== | ||
Line 37: | Line 36: | ||
|| There are three wires that need to be soldered onto the Airwick PCB. These connect power/ | || There are three wires that need to be soldered onto the Airwick PCB. These connect power/ | ||
|| We cut away the plastic part that used to hold the canister. This allows better access to the HAHnode PCB.\\ Initially I left too much tube, the arrow shows where to cut, I used a hacksaw, just above the tongues. || {{6783272238_1202d4a576_b.jpg? | || We cut away the plastic part that used to hold the canister. This allows better access to the HAHnode PCB.\\ Initially I left too much tube, the arrow shows where to cut, I used a hacksaw, just above the tongues. || {{6783272238_1202d4a576_b.jpg? | ||
- | || Wire up the LDR sensor. Don't forget to fit the little white grommet - this makes for a nicer finish when the LDR is mounted in the Airwick case. || {{http:// | + | || Wire up the LDR sensor. Obviously, polarity of the connection is unimportant. Don't forget to fit the little white grommet - this makes for a nicer finish when the LDR is mounted in the Airwick case. || {{http:// |
- | || Wire up the DS18B20 Temp sensor. The insulation tube that is supplied is heatshrink. A quick blast from your heatshrink gun (or a paint stripper gun) will do the job. || {{6783273502_f2bfcdaa68_b.jpg? | + | || Wire up the DS18B20 Temp sensor. Image shows the flat face of the part facing the camera. The insulation tube that is supplied is heatshrink. A quick blast from your heatshrink gun (or a paint stripper gun) will do the job. || {{6783273502_f2bfcdaa68_b.jpg? |
|| Attach sensors || {{6929391161_584aa1d219_b.jpg? | || Attach sensors || {{6929391161_584aa1d219_b.jpg? | ||
|| Fit components into the case.\\ Note the RED mating battery connector now mounted on the RoomNode PCB. || {{6783274192_27a946aa67_b.jpg? | || Fit components into the case.\\ Note the RED mating battery connector now mounted on the RoomNode PCB. || {{6783274192_27a946aa67_b.jpg? |